CR100 cyclic interrupter
Réf. DIP-104
Compact CR100 cyclic interrupter for On/Off measurements on a single-rectifier structure or galvanic anodes. Dry contact with no voltage drop, breaking capacity 20 A / 60 V.
CR100 cyclic interrupter: overview
The CR100 is a very easy-to-use interrupter for taking On/Off measurements on structures with a single cathodic protection rectifier. Compact, it fits in the technician's toolbox. Its dry contact causes no voltage drop, unlike electronic relays, which also makes it usable on galvanic anodes.
It offers three switching cycles: 4 s (3 s On / 1 s Off), 15 s (12 s On / 3 s Off) and 30 s (27 s On / 3 s Off), with a breaking capacity of 20 A at 60 V. For higher currents (50 to 200 A) and GPS synchronisation, IPSI Solutions offers other cyclic interrupters.
Why interrupt the current during measurement
A potential measured while the rectifier is delivering current includes a voltage drop in the soil that makes it look more negative than it is. To check the protection criterion, the potential is measured just after the current is switched off: the OFF potential. The CR100 performs these interruptions cyclically and regularly, so both values can be read in turn.
CR100 or GPS interrupter?
The CR100 is sufficient when a single rectifier feeds the structure. With several, all sources must be switched at the same instant, otherwise the reading is distorted by those still delivering current: GPS-synchronised interrupters are then required, as they are for currents above 20 A.
CR100 cyclic interrupter: technical specifications
| Type | CR100 cyclic interrupter |
| Use | On/Off measurements (single rectifier or galvanic anodes) |
| Contact | Dry (no voltage drop) |
| Cycles | 4 s (3/1), 15 s (12/3), 30 s (27/3) |
| Breaking capacity | 20 A at 60 V |
| Format | Compact (toolbox) |
CR100 cyclic interrupter: documentation
Demande de prix
Ajoutez ce produit à votre demande et envoyez-la en une seule fois depuis le formulaire.
Documentation
Related products






A cathodic protection project?
Our engineers are at your disposal to study your requirements and propose custom-built solutions.
Réponse rapide
Sous 48h
Expertise certifiée
Ingénieurs NACE
Support continu
Maintenance 24/7