Services for buried networks
We help network operators with tracing, marking, and assist them on instrumented pig inspection services.
Our services
Continuous monitoring of your networks
IPSI Solutions covers the entire lifecycle of your anti-corrosion protection systems, from design to operational monitoring.
Surveying and marking
Precise location of your buried networks using electromagnetic detection and field marking compliant with NF S70-003.
Corrosion diagnostics
Potential measurements (CIPS, DCVG, ACVG), protection status assessment and identification of at-risk zones.
Preventive maintenance
Periodic visits, potential checks and adjustments to maintain the effectiveness of your systems.
Site surveillance
Implementation of permanent surveillance for high-risk sites, ensuring compliance with safety instructions established during risk analysis.
Monitoring and reporting
Works surveillance and pig tracking
Our technicians monitor your worksites and track intelligent pig inspection operations.
Third-party works surveillance
On-site presence and monitoring during works near your networks to prevent damage.
Acceptance measurements
Quality control of coatings and cathodic protection effectiveness after works.
Intervention reports
Complete documentation of every intervention, historical tracking and improvement recommendations.
Continuous monitoring
Installation of permanent measurement systems with remote data transmission to your control centre.

Field surveying and marking

Third-party site surveillance
Intelligent pig tracking
Intelligent pig tracking (ILI — In-Line Inspection) detects internal and external defects in your pipelines without service interruption. Our teams handle field marking, passage tracking and data analysis.
100%
Territory coverage
48h
Response time
10+
Years of experience
24/7
Emergency on-call
What to expect from a buried network protection contractor
Buried network protection is a field where the quality of a service provider is hard to judge from a quotation. Here is what actually separates one from another.
Certified personnel, not just certified equipment
Cathodic protection competence is certified for individuals under EN 15257, by level and by application sector. Asking which level operates on your network, and in which sector, is a more useful question than asking about the brand of the rectifier.
Measurement method, not just measurement values
A potential reading means nothing without its method. Was the current interrupted? Were all sources synchronised? Where was the reference electrode placed? A report that does not state these things cannot be used to demonstrate compliance.
Coverage of the whole route
Protection is not demonstrated at the rectifier station. Current attenuates along the line, faster where the coating has degraded. A serious campaign covers the extremities and the singular points — crossings, casings, connections to third-party networks.
Ability to act on what is found
A diagnosis that ends in a report has limited value. Locating a coating defect is useful only if someone can excavate, repair the coating, adjust the protection and verify the result — ideally the same organisation, so that nothing is lost between the finding and the fix.
Equipment used on these operations
The instruments and consumables our teams use on site are available from our catalogue.
Measuring instruments34 products
Voltmeters, data loggers, GPS-synchronised current interrupters.
Reference electrodes13 products
Portable and permanent electrodes for potential surveys.
Instrumentation9 products
Pig signallers, sensors and pipeline monitoring.
Pigging equipment23 products
Pigs, foam pistons and inflatable spheres.
L'académie IPSI Solutions
Restez informé des dernières innovations et bonnes pratiques en protection cathodique
Protection cathodique par courant imposé (ICCP) : principes, avantages et mise en œuvre
Le courant imposé (ICCP) est la méthode de choix pour les grands réseaux. Principes, avantages, composants et dimensionnement.
Mise en service d'un redresseur de protection cathodique
La mise en service du redresseur est le moment où votre investissement en protection cathodique produit ses premiers résultats — ou ses premiers échecs.
Installation d'anodes et backfill en forage : le guide terrain
Un déversoir anodique mal installé gaspille votre courant et réduit la durée de vie de vos anodes. Backfill, tranchée, forage sec et noyé, protocole MMO en 14 étapes : le guide terrain complet.
Need an intervention on your networks?
Contact our technicians to schedule a diagnostic or intervention. Guaranteed response within 48h.
Réponse rapide
Sous 48h
Expertise certifiée
Ingénieurs NACE
Support continu
Maintenance 24/7