EXFS 100 KU spark gap (zone 1)

Réf. DIP-125

Flameproof EXFS 100 KU isolating spark gap for zone 1 (Ex d IIC T6). Lightning current 100 kA (10/350 µs), sparkover voltage ≤1.25 kV, IP67, 2×25 mm² cable.

Description

The EXFS 100 KU is an isolating spark gap to NF EN / IEC 62561-3 (IPSI ref. DEH 923101), intended for lightning protection in explosion-risk zones (zone 1). It offers a lightning current (10/350 µs) Iimp of 100 kA (withstand class H), a rated continuous AC voltage of 250 V (50/60 Hz) and an impulse sparkover voltage ≤1.25 kV.

Its operating temperature is -40 to +60 °C (mounting -5 to +50 °C), with an IP67 rating. The watertight injection-moulded plastic enclosure measures 123 mm × Ø34 mm; connection is by NYY-J 1×25 mm² cable (2 × ~2000 mm). Gas markings II 2 G Ex d IIC T6 Gb and dust II 2 D Ex tb IIIC T80 °C Db; ATEX (DEKRA 11ATEX0178 X) and IECEx (KEM 09.0051X) certifications.

Caractéristiques techniques

TypeIsolating spark gap EXFS 100 KU (NF EN/IEC 62561-3)
IPSI ref.DEH 923101
ATEX zoneZone 1 – Ex d IIC T6 Gb / Ex tb IIIC T80 °C Db
Lightning current (10/350) Iimp100 kA (class H)
Rated voltage (50/60 Hz)250 V
Impulse sparkover voltage≤ 1.25 kV
Temperature-40 to +60 °C (mounting -5 to +50 °C)
Protection ratingIP67
EnclosureInjection-moulded plastic, 123 mm × Ø34 mm
ConnectionNYY-J 1×25 mm² cable (2 × ~2 m)

Demande de prix

Ajoutez ce produit à votre demande et envoyez-la en une seule fois depuis le formulaire.

Back to catalogue