CorrReader PRO
Réf. DIP-155
CorrReader PRO potential recorder for non-specialist technicians: continuous DC/AC On/Off logging with GPS, time-stamping and SD card. Watertight, 2-year warranty.
Description
The CorrReader PRO records DC and AC values, On and Off, with date, time, GPS position and user comments. Designed for technicians who are not corrosion specialists, it continuously logs On/Off values up to 24 h per interruption cycle. Its internal GPS (programmable local-time offset) and SD-card memory in CSV format remove handwritten notes, with no special software. It is supplied complete: insulated-clip leads, mini-USB cable, AC and 12 V DC chargers, Cu/CuSO₄ half-cell, case and manual. 2-year warranty.
On the measurement side: DC ±10 V (resolution 0.1 mV, accuracy 0.05% full scale), true RMS AC 100 V (resolution 0.1 V, accuracy 0.5%), input impedance 20 MΩ, AC rejection <-80 dB from 50 to 60 Hz, operating temperature 5 to 55 °C. Sunlight-readable 16×4 LCD display, 6-key membrane keypad, long-life Li-ion 3.6 V battery rechargeable by USB, watertight 5-way terminals.
Caractéristiques techniques
| Type | CorrReader PRO potential recorder |
| DC measurement | ±10 V (resolution 0.1 mV, accuracy 0.05%) |
| AC measurement | True RMS 100 V (resolution 0.1 V, accuracy 0.5%) |
| Input impedance | 20 MΩ |
| AC rejection | <-80 dB (50-60 Hz) |
| GPS | Internal (programmable offset) |
| Memory | SD card, CSV file |
| Display | Sunlight-readable 16×4 LCD |
| Battery | Li-ion 3.6 V (USB charging) |
| Warranty | 2 years |
Documentation
Demande de prix
Ajoutez ce produit à votre demande et envoyez-la en une seule fois depuis le formulaire.
Documentation
A cathodic protection project?
Our engineers are at your disposal to study your requirements and propose custom-built solutions.
Réponse rapide
Sous 48h
Expertise certifiée
Ingénieurs NACE
Support continu
Maintenance 24/7